In
the operation of brain stereotaxic devices, it is often necessary to
perform microinjection on animals. An automatic microinjection pump is
used, which is convenient to use. The syringe syringe is directly
installed on the gripper, and the precise movement of the syringe piston
is controlled by the microcomputer control driving unit to directly
inject or recover liquids from experimental animals, avoiding errors
caused by catheter methods.
M5259 dual channel high-precision
microinjection pump, high-definition touch screen operation, Ditronstep
micro step control system, used for precise control and delivery of
trace liquid drugs or solutions. It is usually used in conjunction with
brain locators or microcontrollers in the medical field, especially in
clinical medicine, laboratory research, and drug development. This
injection pump is compatible with most imported and domestic
microinjectors (0.5ul -1000ul), with a stroke resolution of 0.190 μ m/μ
step, a linear velocity range of 0.12 μ m/min to 121.92mm/min (flow
rate=linear velocity x syringe loading area), and a propulsion distance
of 70mm.
Functional Features
1. Operation mode: independent, reciprocating, synchronous, synchronous merging
2. Working mode: infusion, extraction, infusion/extraction, extraction/infusion, continuous, multiple infusion
3. Touch display: 800 * 480 5-inch high-definition touch screen, easy to operate, clear and concise information
4. Language types: Chinese and English, 2 languages to choose from
5. Online speed regulation: adjust the current flow rate without stopping the machine during operation
6.
Calibration function: Each channel injector can be independently
calibrated and calibration parameters can be stored independently
7.
Syringe selection: Built in from major domestic and foreign
manufacturers, with a choice of main models of syringes and support for
customization
8. Parameter settings: Each channel can independently
set liquid volume, flow rate, infusion time, extraction time, interval
time, and store them independently
9. Reminder function: Real time
display of available Min/Max flow rates for each channel; Dynamically
display the operating parameters of each channel
10. Reminder function: Each channel will run to its set target liquid volume, and sound alarms will alert each other
11. Thrust setting: Each channel sets the appropriate thrust according to its own injector specifications
12. External control function: External level or pulse signal to achieve independent start stop control of each channel
13. Communication control: RS485/USB optional, touch settings for address and baud rate
14. Status output: Each channel independently outputs start stop and direction status
Technical Parameter
1. Number of channels: Dual channels
2. Operation mode: independent, reciprocating, synchronous, synchronous merging
3. Working mode: infusion, extraction, infusion/extraction, extraction/infusion, continuous, multiple infusion
4. Touch display: 800 * 480 5-inch high-definition touch screen
5. Maximum travel: 70mm
6. Accuracy:<1%
7. Repetitive accuracy: Error ≤ ± 0.1%
8. Sample injector specifications: 0.5 μ L to 1000 μ L
9. Linear thrust: ≥ 25N
10. Linear speed range: 0.12 μ m/min to 121.92mm/min
11. Step resolution: 0.190 μ m/μ step
12. Applicable power supply: AC 90V~264V 50/60Hz
13. Working environment: Temperature: 0-40 ℃ Humidity: Humidity 20% -80% RH No condensation
14. Storage environment: Temperature: -10~60 ℃ Humidity: 20% -80% RH No condensation
15. Protection level: IP31
16. Product size (mm): Controller: 240 * 149 * 87.5 (mm) Execution structure: 163 * 34 * 34 (mm)
Applicable Syringes
Optional syringe capacity | Inner diameter of syringe(mm) | Reference flow range(nL/min-mL/min) | Optional syringe capacity | Inner diameter of syringe(mm) | Reference flow range(nL/min-mL/min) |
0.5ul | 0.103 | 0.0007~0.0013 | 250ul | 2.304 | 0.3335~0.6671 |
1ul | 0.146 | 0.0013~0.0027 | 500ul | 3.256 | 0.6658~1.3322 |
2ul | 0.206 | 0.0027~0.0053 | 1ml |
4.73 |
1.4060~2.8110 |
5ul | 0.343 |
0.0074~0.0148 |
2ml |
8.92 |
4.9990~9.9980 |
10ul | 0.485 | 0.0148~0.0295 | 2.5ml |
8.92 |
4.9990~9.9980 |
25ul | 0.729 | 0.0334~0.0668 | 5ml |
12.4 |
9.6620~19.3220 |
50ul | 1.03 | 0.0667~0.1333 | 10ml |
14.87 |
13.8940~27.7860 |
100ul | 1.457 | 0.1334~0.2668 |
Ordering Information
Model | Name | Trip(mm) |
M5126 | Manual microinjection pump | 0-25 |
M5136 | Manual microinjection pump | 0-50 |
M5258 | High precision microinjection pump | 0-70 |
M5259 | Dual channel high-precision microinjection pump | 0-70 |
M5260 | Microinjection pump | 0-150 |
M5261 | Dual channel microinjection pump | 0-150 |
M5262 | Four channel microinjection pump | 0-150 |
M5263 | Ultra precision microinjection pump | 0-150 |
M5264 | Dual channel independent control microinjection pump | 0-150 |
Selection Guide
M5136 Manual microinjection pump |
M5258 High precision microinjection pump |
M5259 Dual channel high-precision microinjection pump |
M5260 Microinjection pump |
M5261 Dual channel microinjection pump |
M5262 Four channel microinjection pump |
M5263 Ultra precision microinjection pump |
M5264 Dual channel independent control microinjection pump |